1. Introduction of TXLP/2R series double guide heating cable
TXLP/2R 220V dual-guide heating cable is mainly used in floor heating, soil heating, snow melting, pipeline heating, etc.
The TXLP/2R 220V dual-guide heating cable assembly adopts an implicit connector, and the hot and cold connector parts remarked with “SPLICE”..
2. Structure of TXLP/2R series double guide heating cable
Outer sheath: polyvinyl chloride (PVC)
Grounding wire: tinned copper wire
Shielding layer: aluminum foil + copper wire
Inner conductor: alloy resistance wire
Internal insulation: cross-linked polyethylene (XLPE)
Connector type: Implicit connector
3. Size of TXLP/2R series double guide heating cable
Outer diameter: 7.8mm
4. Electrical parameters of TXLP/2R series double guide heating cable
Supply voltage: 220V (voltage can be customized)
Linear power: 17W/m 18.5W/m
5. Others
Cold line length: 2.25m
Maximum surface working temperature: 65℃
Minimum bending coefficient: 5D
Electric heating 17W/M double-lead Non-cropped (PVC) heating cable specifications
Voltage (V) |
Model NO. |
Power |
Standard length (M) |
Power per meter (W/M) |
Total resistance value (Ω) |
220 |
TXLP/2/17 |
3300 |
194 |
17 |
14.7 |
220 |
TXLP/2/17 |
3000 |
176 |
17 |
16.1 |
220 |
TXLP/2/17 |
2800 |
165 |
17 |
17.3 |
220 |
TXLP/2/17 |
2600 |
153 |
17 |
18.6 |
220 |
TXLP/2/17 |
2400 |
141 |
17 |
20.2 |
220 |
TXLP/2/17 |
2200 |
129 |
17 |
22.0 |
220 |
TXLP/2/17 |
2000 |
118 |
17 |
24.2 |
220 |
TXLP/2/17 |
1700 |
100 |
17 |
28.5 |
220 |
TXLP/2/17 |
1370 |
81 |
17 |
35.3 |
220 |
TXLP/2/17 |
1250 |
74 |
17 |
38.7 |
220 |
TXLP/2/17 |
1000 |
59 |
17 |
48.4 |
220 |
TXLP/2/17 |
840 |
49 |
17 |
57.6 |
220 |
TXLP/2/17 |
700 |
49 |
17 |
69.1 |
220 |
TXLP/2/17 |
600 |
41 |
17 |
80.7 |
220 |
TXLP/2/17 |
500 |
29 |
17 |
96.8 |
220 |
TXLP/2/17 |
400 |
24 |
17 |
121.0 |
220 |
TXLP/2/17 |
300 |
18 |
17 |
161.3 |
220 |
TXLP/2/17 |
1610 |
161 |
10 |
30.1 |
220 |
TXLP/2/17 |
1300 |
130 |
10 |
37.2 |
220 |
TXLP/2/17 |
1050 |
105 |
10 |
46.1 |
220 |
TXLP/2/17 |
940 |
94 |
10 |
51.5 |
220 |
TXLP/2/17 |
760 |
76 |
10 |
63.7 |
220 |
TXLP/2/17 |
530 |
53 |
10 |
91.3 |
220 |
TXLP/2/17 |
380 |
38 |
10 |
127.4 |
220 |
TXLP/2/17 |
230 |
23 |
10 |
210.4 |
Electric heating 18.5W/M double-lead Non-cropped (PVC) heating cable specifications
Voltage (V) |
Model NO. |
Power |
Standard length (M) |
Power per meter (W/M) |
Total resistance value (Ω) |
220 |
TXLP/2/18 |
3150 |
170 |
18.5 |
15.4 |
220 |
TXLP/2/18 |
3000 |
162 |
18.5 |
16.1 |
220 |
TXLP/2/18 |
2800 |
151 |
18.5 |
17.3 |
220 |
TXLP/2/18 |
2600 |
141 |
18.5 |
18.6 |
220 |
TXLP/2/18 |
2400 |
130 |
18.5 |
20.2 |
220 |
TXLP/2/18 |
2200 |
119 |
18.5 |
22.0 |
220 |
TXLP/2/18 |
2000 |
108 |
18.5 |
24.2 |
220 |
TXLP/2/18 |
1800 |
97 |
18.5 |
26.9 |
220 |
TXLP/2/18 |
1600 |
86 |
18.5 |
30.2 |
220 |
TXLP/2/18 |
1370 |
74 |
18.5 |
35.3 |
220 |
TXLP/2/18 |
1250 |
68 |
18.5 |
38.7 |
220 |
TXLP/2/18 |
1000 |
54 |
18.5 |
48.4 |
220 |
TXLP/2/18 |
840 |
45 |
18.5 |
57.6 |
220 |
TXLP/2/18 |
700 |
38 |
18.5 |
69.1 |
220 |
TXLP/2/18 |
600 |
32 |
18.5 |
80.7 |
220 |
TXLP/2/18 |
500 |
27 |
18.5 |
96.8 |
220 |
TXLP/2/18 |
400 |
22 |
18.5 |
121.0 |
220 |
TXLP/2/18 |
300 |
16 |
18.5 |
161.3 |